FABRICATION OF SOCKS MEN'S WOOL DARK OG
Specification:- Fabrication (Knitting, Linking, Asst. to Linking, Washing, Pressing, Checking and Darning) of Socks Men’s Wool Dark OG, As per Specification no. PROV/OCFS/SOCKS/ARMY/NEW 64(a) & ANNEXURE-“A1”
Specification
FABRICATION OF SOCKS MEN'S WOOL DARK OG
Specification:- Fabrication (Knitting, Linking, Asst. to Linking, Washing, Pressing, Checking and Darning) of Socks Men’s Wool Dark OG, As per Specification no. PROV/OCFS/SOCKS/ARMY/NEW 64(a) & ANNEXURE-“A1”
Drawing no.
Manufacturing Technology
as per attached list (Manufacturing Technology Files )
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
1)Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
Fabric Nylon 220 GSM White Water and Oil repellent 100 cm. Specification No.IND/TC/0160 EXCEPT TEST PARAMETERS Water Vapour Transmission and Air permeability not to be tested.
Specification
Fabric Nylon 220 GSM White Water and Oil repellent 100 cm. Specification No.IND/TC/0160 EXCEPT TEST PARAMETERS Water Vapour Transmission and Air permeability not to be tested.
Drawing no.
Manufacturing Technology
as per attached list (Manufacturing Technology Files )
1) Chemical & Mechanical properties as per std. given drawing /Specification.
2) Dimensional inspection for all dimension given in the drawing & other parameter which are mentioned in relevant drawing/specification.
COTTON FABRIC FOR S.D. PARACHUTE type II of IS:2970-1987 Reffirmed 2004 There shall be no presence of starch in appearance workmanship and finish and other respects not denined in the specification the material shall conform to the sealed pattern held in the custody of CQAT&C Kanpur. The bolt length/Roll length 40.00 Mtr. or above.
2.PACKING AND MARKING : As per relevant clause of specn.
Snap Fastener Top 7/7 & Bottom 7/7 in Four Parts (Cap of Top Covered with Dark Brown Sheeting)
Specification:- IS:4741-1968 (reaffirmed 2008) Unit – set contains 10 set Snap fastener 7/7 bottom in two parts and 12 set Snap fastener 7/7 Top in two parts are equal to 01 set
Specification
Snap Fastener Top 7/7 & Bottom 7/7 in Four Parts (Cap of Top Covered with Dark Brown Sheeting)
Specification:- IS:4741-1968 (reaffirmed 2008) Unit – set contains 10 set Snap fastener 7/7 bottom in two parts and 12 set Snap fastener 7/7 Top in two parts are equal to 01 set
Drawing no.
Manufacturing Technology
as per attached list (Manufacturing Technology Files )
Electrical Control Panel Complete with Accessories as per Annexure A QTY 1 No
Specification
Electrical Control Panel Complete with Accessories as per Annexure A QTY 1 No
Drawing no.
Manufacturing Technology
a) Loading of Components:- The panel of components including flat parts ( Doors, Rear Panels, Top & Bottom Covers, Gland Plates and Side Panels etc) . Compact Enclosures are loaded at this stage .
b) Pre Treatment- Stage I:- In this zone, all the oil grease and foreign impurities are cleaned.
c) Pre Treatment- Stage II:- This is done in different stages using water jets, which flush down all chemicals from stage I on the surface or the edges.
d) Pre treatment StageIII :- This is done in different stages using fresh DM water jets, which flush down all chemicals from stage II on the surface of edges.
e) Pretreatment stage IV- Here the panes are uniformly coated with a special Nano-ceramic coating bone rite NT-1 ( replacing the commonly used phosphating process) applied by high pressure jets.
f) Pre Treatment Stage V- This is done in different stages using water jets, which flush down all dissolved salts on the surface of the edges.
g) Pretreatment –Stage VI- In this final pre treatment