Name
Code
Quantity
Approx Value
Select
MACHINING OF VENTURI FOR 84MM RL MK III FROM SINGLE PIECE PYT FORGING BLANK TO VENTURI IN SEMI FINISHED CONDITION
Physical Verification needed
Description
MACHINING OF VENTURI FOR 84MM RL MK III FROM SINGLE PIECE PYT FORGING BLANK (DRG. NO. M-10857B) TO VENTURI IN SEMI FINISHED CONDITION (DRG. NO. M-11593)
Specification
MACHINING OF VENTURI FOR 84MM RL MK III FROM SINGLE PIECE PYT FORGING BLANK (DRG. NO. M-10857B) TO VENTURI IN SEMI FINISHED CONDITION (DRG. NO. M-11593)
Testing / Inspection Facility
91
1251
Number
DRIVING SHAFT OPERATION 10 TO 70 SEMI MACHINED FORGING TO DRG NO 172 40 314 SMF TO LF 3951040047
Physical Verification needed
Description
DRIVING SHAFT OPERATION 10 TO 70 SEMI MACHINED FORGING TO DRG. NO. 172.40.314/SMF
Specification
GOST 4543-71
Drawing no.
172.40.314/SMF
Testing / Inspection Facility
39
363
Number
HAVERSACK MEDICAL UNIVERSAL COMPLETE
Description
HAVERSACK MEDICAL UNIVERSAL COMPLETE
Specification
IND/GS/1541 AND DRAWING NO. IND/TC/1005(G)
Testing / Inspection Facility
20
AS PER TENDER
Number
FABRIC NYLON 65 GMS RIP STOP WR OG PU COATED WIDTH 160 CM
Description
FABRIC NYLON 65 GMS RIP STOP WR OG PU COATED WIDTH 160 CM
Specification
AS PER APPENDIX – A OF PROV SPEC NO S/6421/BAG SLEEPING LT WT/TC - 6
Testing / Inspection Facility
20
AS PER TENDER
Metre
SALITAH LARGE FOR TENTS COMPLETE
Description
SALITAH LARGE FOR TENTS COMPLETE
Specification
JSS – 8340 - 18
Testing / Inspection Facility
20
AS PER TENDER
Number
CLOTH COTTON 375 GMS SCOURED WR FOR CAPES 91 CMS WIDE
Description
CLOTH COTTON 375 GMS SCOURED WR FOR CAPES 91 CMS WIDE
Specification
IS:2422-1985 (REAFFIRMED 1999) WITH AMENDMENT NO.1 OF AUG., 95 AND AMENDMENT NO 2 OF NOV 95
Testing / Inspection Facility
99
AS PER TENDER
Metre
FABRIC NYLON PU COATED WATER PROOF OG 115 GSM WIDTH 180 Plus 2 CMS NO NEGATIVE TOLERANCE
Description
FABRIC NYLON PU COATED WATER PROOF OG 115 GSM WIDTH 180 +2 CMS NO NEGATIVE TOLERANCE
Specification
PROV SPECIFICATION NO S/6421/BAG SLEEPING LT WT/TC-6
Testing / Inspection Facility
20
AS PER TENDER
Metre
FABRIC NYLON 50 GMS RIP STOP WR OG PU COATED WIDTH 160 CM
Description
FABRIC NYLON 50 GMS RIP STOP WR OG PU COATED WIDTH 160 CM
Specification
AS PER APPENDIX – A OF PROV SPEC NO S/6421/BAG SLEEPING LT WT/TC - 6
Testing / Inspection Facility
20
AS PER TENDER
Metre
HAND GUARD ASSEMBLY SK 6624 TE
Physical Verification needed
Description
HAND GUARD ASSEMBLY SK- 6624/TE
Specification
HAND GUARD ASSEMBLY SK- 6624/TE
Manufacturing Technology
METAL FORMING, CASTING, MACHINING AND MOULDING
Testing / Inspection Facility
Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing Chemical and mechanical properties as per std. given drawing.
70
174637
Number
MAGAZINE ASSEMBLY SK 6614 TE
Physical Verification needed
Description
MAGAZINE ASSEMBLY SK- 6614/TE
Specification
MAGAZINE ASSEMBLY SK- 6614/TE
Manufacturing Technology
METAL FORMING MIM, COILING, MACHINING AND MOULDING
Testing / Inspection Facility
Chemical and mechanical properties as per std. given drawing. Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing
70
174637
Number
OILER ASSEMBLY SK 6641 TE
Physical Verification needed
Description
OILER ASSEMBLY SK- 6641/TE
Specification
OILER ASSEMBLY SK- 6641/TE
Testing / Inspection Facility
Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing Chemical and mechanical properties as per std. given drawing.
70
174637
Number
FORE GRIP ASSEMBLY SK 6632 TE
Physical Verification needed
Description
FORE GRIP ASSEMBLY SK- 6632/TE
Specification
FORE GRIP ASSEMBLY SK- 6632/TE
Manufacturing Technology
METAL FORMING,MACHINING AND MOULDING
Testing / Inspection Facility
Chemical and mechanical properties as per std. given drawing. Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing
70
174637
Number
FORE END RING ASSEMBLY SK 6545 TE
Physical Verification needed
Description
FORE END RING ASSEMBLY SK- 6545/TE
Specification
FORE END RING ASSEMBLY SK- 6545/TE
Drawing no.
SK- 6543/TE, SK-6544/TE SK- 6545/TE
Testing / Inspection Facility
Chemical and mechanical properties as per std. given drawing. Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing
70
174637
Number
COVER WITH REINFORCING PLATE SK6549 TE
Physical Verification needed
Description
COVER WITH REINFORCING PLATE SK-6549/TE
Specification
COVER WITH REINFORCING PLATE SK-6549/TE
Drawing no.
SK- 6546/TE SK-6549/TE SK-6612/TE
Testing / Inspection Facility
Chemical and mechanical properties as per std. given drawing. Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing
70
174637
Number
RAIL SK 6548 TE
Physical Verification needed
Description
RAIL SK-6548/ TE
Specification
RAIL SK-6548/ TE
Testing / Inspection Facility
Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing Chemical and mechanical properties as per std. given drawing.
70
174637
Number
RIVET SK 6529 TE
Physical Verification needed
Description
RIVET SK- 6529/ TE
Specification
RIVET SK- 6529/ TE
Testing / Inspection Facility
Chemical and mechanical properties as per std. given drawing. Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing
70
174637
Number
SHAFT TORSION FORGING TO DRG NO 172 51 016 F TO LF 3996411023
Physical Verification needed
Description
SHAFT TORSION FORGING TO DRG NO 172.51.016/F
Specification
GOST 4543-71
Testing / Inspection Facility
39
192
Number
RH MIDDLE ENGAGING RING TO DRG NO 172 40 329 F TO LF 3901040062
Physical Verification needed
Description
RH MIDDLE ENGAGING RING TO DRG NO 172.40.329/F
Specification
GOST 4543-71
Testing / Inspection Facility
39
43
Number
FABRIC NYLON PU COATED WATER PROOF OG 115 GSM WIDTH 180 Plus 2 CMS NO NEGATIVE TOLERANCE
Description
FABRIC NYLON PU COATED WATER PROOF OG 115 GSM WIDTH 180 +2 CMS NO NEGATIVE TOLERANCE
Specification
PROV SPECIFICATION NO S/6421/BAG SLEEPING LT WT/TC-6
Testing / Inspection Facility
20
AS PER SPECIFICATION
Metre
BRANCH PIPE ASSY TO LF NO 6206803064
Physical Verification needed
Description
175.04.004CB-1
Specification
175.04.004CB-1
Drawing no.
175.04.004CB-1
Manufacturing Technology
AS PER VQC ATTACHED - - - -
Testing / Inspection Facility
AS PER VQC ATTACHED - - - -
62
15
Number
SETTING PIECE AL8604431 LF 7445191497
Physical Verification needed
Description
SETTING PIECE AL8604431 LF 7445191497
Testing / Inspection Facility
74
124
Number
PIN AL8960294 LF 7445108229
Physical Verification needed
Description
PIN AL8960294 LF 7445108229
Testing / Inspection Facility
74
174
Number
FLANGE DRG NO Y7493388 LF NO 7440207515
Physical Verification needed
Description
FLANGE DRG NO Y7493388 LF NO 7440207515
Specification
FLANGE DRG NO Y7493388 LF NO 7440207515
Testing / Inspection Facility
74
115
Number
CARDEN HEAD AL8236256 LF 7440206006
Description
CARDEN HEAD AL8236256 LF 7440206006
Testing / Inspection Facility
74
154
Number
BASE LF 7440205774
Physical Verification needed
Description
BASE LF 7440205774
Specification
BASE LF 7440205774
Testing / Inspection Facility
74
324
Number
SETTING PIECE AL8604589 LF 7440201617
Physical Verification needed
Description
SETTING PIECE AL8604589 LF 7440201617
Testing / Inspection Facility
74
89
Number
PULLEY AL8322056 LF 7440200773
Physical Verification needed
Description
PULLEY AL8322056 LF 7440200773
Testing / Inspection Facility
74
160
Number
Cleaning Rod Drg No SK 6574 TE
Physical Verification needed
Description
Cleaning Rod Drg No. SK- 6574/ TE
Specification
Cleaning Rod Drg No. SK- 6574/ TE
Testing / Inspection Facility
Chemical and mechanical properties as per std. given drawing. Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing
70
174637
Number
MANUFACTURE AND SUPPLY OF MGL BUSH EXTRACTOR BEFORE ANODIC COATING TO DRG NO TEND 2261 ST WITH FIRMS MATERIAL
Physical Verification needed
Description
MANUFACTURE AND SUPPLY OF MGL BUSH EXTRACTOR BEFORE ANODIC COATING TO DRG NO TEND 2261 ST WITH FIRMS MATERIAL
Specification
MANUFACTURE AND SUPPLY OF MGL BUSH EXTRACTOR BEFORE ANODIC COATING TO DRG NO TEND 2261 ST WITH FIRMS MATERIAL
Drawing no.
TEND 2261 STAR
Testing / Inspection Facility
70
450
Ample
Accessories in Container Assembly SK 6601 TE
Physical Verification needed
Description
Accessories in Container Assembly SK 6601 TE
Specification
Accessories in Container Assembly SK 6601 TE
Manufacturing Technology
FOR SK-6603/TE & SK-6604/TE- Metal forming,
For SK-6605/TE- Four sided swaging
For SK-6606/TE-Twisting
For SK-6607/TE, SK-6608/TE, SK-6609/TE and SK-6610/TE- Machining
Testing / Inspection Facility
1-Chemical and mechanical properties as per std. given drawing. 2- Dimensional inspection, for all dimensions given in the drawing a other parameter which are mentioned in relevant drawing
70
176637
Number