26321
OLF/MM-2/T-1706011808
Opto Electronic Factory
Dehradun
Dehradun
Dehradun
Dehradun, Uttaranchal
248008
26322
OLF/MM-2/T-1706011809
Opto Electronic Factory
Dehradun
Dehradun
Dehradun
Dehradun, Uttaranchal
248008
26323
128MMETT18001172/G685EO0333
Ordnance Factory Tiruchirapalli
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
26324
EOI/L/PV/18
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
Name
Code
Quantity
Approx Value
Select
HINGE PIN
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Kilogram
PIN TENT ANGLE IRON MED.MK-2 - AF
Description
CQA(GS)/US/428 (5877/PK), CADMIUM PLATED AS PER IS:1572-1986
Specification
CQA(GS)/US/428 (5877/PK), CADMIUM PLATED AS PER IS:1572-1986
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
PIN CARBON STEEL SMALL - AF
Description
IND/GS/1630 (5836/PK), CADMIUM PLATED AS PER IS:1572-1986
Specification
IND/GS/1630 (5836/PK), CADMIUM PLATED AS PER IS:1572-1986
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
LOCKING CLIP 60 MM
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
CLIP 60MM
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
WIRE NAILS IRON ROUND SHANK 150MM X 6 SWG
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
ROOF POLE WITH THREE WAY JOINT (FOR TENT EXTENDABLE)
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
HEATER SPACE OIL BURNING-CONTROL VALVE BODY
Description
IS: 10742-1983 GR.-I OF TABLE-I FOR GUN METAL.
Specification
IS: 10742-1983 GR.-I OF TABLE-I FOR GUN METAL.
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
LOCATING PIN DET 6/3
Description
OEF DRG. NO. SK - 966/A
Specification
OEF DRG. NO. SK - 966/A
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
FOUR WAY JOINT ALUMINIUM ALLOY DIE CASTING TO IS: 617
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
FOUR WAY JOINT CADMIUM PLATED FOR A/F
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
FLAT PLIERS 7814-0091 U 15X10
Description
NO. GOST-5547-86
Specification
NO. GOST-5547-86
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
26325
EOI/K/PV/18
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
26326
OLF/MM-2/T-1706041794
Opto Electronic Factory
Dehradun
Dehradun
Dehradun
Dehradun, Uttaranchal
248008
Name
Code
Quantity
Approx Value
Select
PUTTY, 200T (LF-9927091205)
Description
PUTTY, 200T AS PER SPEC. NO. OST3-5605-91
Specification
PUTTY, 200T AS PER SPEC. NO. OST3-5605-91
Testing / Inspection Facility
99
16
Kilogram
PUTTY, 135P (LF-9927084768)
Description
PUTTY, 135P AS PER SPEC. NO. OST-5605-91
Specification
PUTTY, 135P AS PER SPEC. NO. OST-5605-91
Testing / Inspection Facility
99
6
Kilogram
PRODUCT YEP-6 (IC TUBE) (LF-7441121134)
Description
PRODUCT YET-6 (IC TUBE), AS PER SPEC. NO. TY ODO.335.451)
Specification
PRODUCT YET-6 (IC TUBE), AS PER SPEC. NO. TY ODO.335.451)
Drawing no.
TY ODO.335.451
Testing / Inspection Facility
74
126
Number
GREASE PROTON (LF-7440301320)
Description
GREASE PROTON AS PER SPEC. NO. TY-38-101.1162-88
Specification
GREASE PROTON AS PER SPEC. NO. TY-38-101.1162-88
Drawing no.
TY-38-101.1162-88
Testing / Inspection Facility
74
98
Kilogram
ELECTRIC UNIT, BL2.300.041CB (LF-7440300983)
Description
ELECTRIC UNIT, BL2.300.041CB (FOR PNK-4S)
Specification
ELECTRIC UNIT, BL2.300.041CB (FOR PNK-4S)
Drawing no.
BL2.300.041CB
Testing / Inspection Facility
74
172
Number
GREEN PUTTY 50M (LF-7440201176)
Description
GREEN PUTTY 50M
Specification
AS PER SPECIFICATION NO. OST3-5605-91
Testing / Inspection Facility
74
12
Kilogram
OPTO MECHANICAL SHUTTER (LF-7440200254)
Description
OPTO MECHANICAL SHUTTER, AL5.964.012 (FOR BLOCK-D)
Specification
OPTO MECHANICAL SHUTTER, AL5.964.012 (FOR BLOCK-D)
Testing / Inspection Facility
74
25
Number
26327
RFI/OTE/ATH1320429/2018-2019
Rifle Factory Ishapur
The General Manager,
Ishapore
Ishapore
West Bengal
743144
26328
128MMETT18001171/G685EO0331
Ordnance Factory Tiruchirapalli
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
Name
Code
Quantity
Approx Value
Select
EXTRACTOR TO DRG NO29P 0020STAR2 required for 0POINT315 Sporting Rifle
Description
EXTRACTOR TO DRG. NO.29P 0020*2 required for 0.315" Sporting Rifle
Specification
AS PER DRG. NO.29P 0020*2 required for 0.315" Sporting Rifle
Testing / Inspection Facility
INSPECTION WILL BE CARRIED OUT AFTER RECEIPT OF MATERIAL AT OFT BY GM OR HIS AUTHORIZED REPRESENTATIVE
03
1201
Number
26329
128MMETT18001170/G225DO0328
Ordnance Factory Tiruchirapalli
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
26330
128MMETT18001163/G685EO0330
Ordnance Factory Tiruchirapalli
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
Name
Code
Quantity
Approx Value
Select
BOLT LOCKING TO DRG NO 29P 0042STAR2 required for 0POINT315 Sporting Rifle
Description
BOLT LOCKING TO DRG.NO.29P 0042*2 required for 0.315" Sporting Rifle
Specification
AS PER DRG.NO.29P 0042*2 required for 0.315" Sporting Rifle
Testing / Inspection Facility
INSPECTION WILL BE CARRIED OUT AFTER RECEIPT OF MATERIAL AT OFT BY GM OR HIS AUTHORIZED REPRESENTATIVE
70
2960
Number
26331
128MMETT180011612G685EO0329
Ordnance Factory Tiruchirapalli
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
26332
128MMETT18001161/G685EO0327
Ordnance Factory Tiruchirapalli
The General Manager,
Tiruchirapalli
Tiruchirapalli
Tamil Nadu
620016
Name
Code
Quantity
Approx Value
Select
STOCK BUTT TO DRG NO 29 P 0038STAR2 required for 0POINT315 Sporting Rifle
Description
STOCK BUTT TO DRG.NO.: 29 P 0038*2 required for 0.315" Sporting Rifle
Specification
AS PER DRG.NO.: 29 P 0038*2 required for 0.315" Sporting Rifle
Testing / Inspection Facility
INSPECTION WILL BE CARRIED OUT AFTER RECEIPT OF MATERIAL AT OFT BY GM OR HIS AUTHORIZED REPRESENTATIVE
70
883
Number
26333
3173001017
Small Arms Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208009
26334
EOI/ENGG GENERIC 3/PV/18
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
Name
Code
Quantity
Approx Value
Select
FABRICATION OF BELT ICK BLACK A/F
Description
AS PER REQUIREMENT & SPECIFICATIONÂÂ
Specification
AS PER REQUIREMENT & SPECIFICATIONÂÂ
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
Fabrication of Tent Fly Outer 4M Unit
Description
AS PER REQUIREMENT & SPECIFICATION
Specification
AS PER REQUIREMENT & SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
26335
EOI/I/PV/18
Ordnance Equipment Factory
The General Manager,
Kanpur
Kanpur
Kanpur, Uttar Pradesh
208001
Name
Code
Quantity
Approx Value
Select
EYELET BRASS NO.28 WITH TURN OVER WASHERBRONZED BLACK
Description
EYELET BRASS NO.28 WITH TURN OVER WASHERBRONZED BLACK
Specification
IS:4084-1978,REAFFIRMED 2013,AMDS 2.
Testing / Inspection Facility
21
AS PER REQUIREMENT
Set
EYELET BRASS NO.21 WITH PLAIN WASHER BRONZED BLACK
Description
EYELET BRASS NO.21 WITH PLAIN WASHER BRONZED BLACK
Specification
AS PER REQUIREMENT AND SPECIFICATION
Testing / Inspection Facility
21
AS PER REQUIREMENT
Set
HAMMER SLADGE DOUBLE FACED 2 KG. WITH HANDLE
Description
HAMMER SLADGE DOUBLE FACED 2 KG. WITH HANDLE
Specification
IS:841-1983 & SUPPL. SCH. CQA(GS)/SS/337(b) (5625/PK) AND AS IN TE.
Testing / Inspection Facility
21
AS PER REQUIREMENT
Number
LONG CLOTH COTTON WHITE BLEACHED 91 CMS
Description
IS:187-1978 (V.NO. 1) WITH AMENDMENT NO. 1 & 2 OF 1986
Specification
IS:187-1978 (V.NO. 1) WITH AMENDMENT NO. 1 & 2 OF 1986
Testing / Inspection Facility
21
AS PER REQUIREMENT
Metre